Multitech MultiModemISDN MTA128ST-USB User Manual page 31

External isdn terminal adapter
Hide thumbs Also See for MultiModemISDN MTA128ST-USB:
Table of Contents

Advertisement

Switch Configuration Commands
Use the following commands to select your network switch type (e.g., EuroISDN Net3)
and to specify other information required to make an ISDN connection.
Command: %A97=n
Function:
Values:
Default:
Description:Standardized ISDN signaling protocols such as DSS1, DSS2, and SS7
Command: !C0=n
Function:
Values:
Default:
Description:Use the !C0= command to select one of the six network switch types
Command: !C6=n
Function:
Values:
Default:
Description:Use !C6= to specify the data service profile identifier (SPID) that the ISDN
Command: *!C6=n
Function:
Values:
Default:
Description:Use *!C6= to specify the voice service profile identifier (SPID) that the ISDN
MTA128ST-USB
Chapter 4 - AT Commands, S-Registers and Result Codes
Dialing Method
n = 0 or 1
%A97=0 (En bloc)
support sending complete indication, (a signal that no more digits follow).
Adding this signal to a telephone number often is impractical. Therefore,
many private networks send the number of a called party using a procedure
called overlap sending, where no sending complete indication is sent.
Computer users can automatically add the sending complete indication to a
telephone number by choosing the en bloc method of sending, which results
in faster call setup. Use the %A97= command to select between the two
methods.
%A97=0
En bloc sending during call SETUP
%A97=1
Overlap sending during call SETUP
Network Switch Type
n = 0, 1, 2, 4, 5, or 6
!C0=2 (Net3)
supported by the TA. Factory default setting is !C0=2 (NET3).
!C0=0
AT&T 5ESS
!C0=1
Northern Telecom DMS-100
!C0=2
EuroISDN NET3
!C0=4
INS64
!C0=5
US NI-1
!C0=6
VN4
Data SPID
n = 0–20 character string
null string
service provider assigned at subscription time. The data SPID string can
have up to 20 characters. This command is not used if the switch type is set
to NET3.
Note: For DMS-100 switches, any ASCII character except the underline (_)
character is valid. For NI-1 and AT&T switches, only the digits 0–9 are valid.
Voice SPID
n = 0- to 20 character string
null string
service provider assigned at subscription time. The voice SPID string can
have up to 20 characters. It is not used if the switch type is set to NET3.
Note: For DMS-100 switches, any ASCII character except the underline (_)
character is valid. For NI-1 and AT&T switches, only the digits 0–9 are valid.
31

Advertisement

Table of Contents
loading

Table of Contents