Faisceaux Numériques T0 - Mitel MiVoice 5000 Installing And Configuring

Ex controller and mitel gx gateway
Hide thumbs Also See for MiVoice 5000:
Table of Contents

Advertisement

INSTALLING AND CONFIGURING MITEL EX CONTROLLER AND MITEL GX GATEWAY
When the PRI slot is assigned (box ticked), a table appears at the bottom to define the type of signalling
(ETSI or QSIG) and the behaviour (master/slave).
Once the choice is made, click Apply Changes.
When the entry is complete, the menu displays the list of assignments and the Ready status of the
corresponding trunks:
FAISCEAUX NUMÉRIQUES T0
These trunks must be connected to the BRI cards of EX Controller.
To configure a digital trunk, a SIP trunk must be created via WebAdmin.
The port of this type of network line must be different from that of 5060 to avoid any clash with the port
of analogue phones, and the value must be unique for an EX / GX.
If several trunks are defined for an EX / GX, the ports must be different, with the values 5062, 5064,...
for example.
If port 5060 or 5061 is defined in the line group configuration, the line group will not be proposed for BRI
configuration.
To facilitate data entry, only eligible SIP trunks, that is those declared with the IP address (or FQDN) of
EX Controller are proposed (the IP address indicated at the top of the screen):
The Trunk drop-down list contains all the SIP trunks declared with the EX/GX IP address or the FQDN.
AMT/PTD/PBX/0173/0/9/EN
12/2019
23