SREL, SREL.ADV, SREL.W SREL.G2,
SREL.G2.W, SREL2.G2

8.1.2 SmartRelay (G2): SREL.G2, SREL.W.G2, SREL2.G2

(Manual)
Autodetection/
both active
This tab ([Configuration/Data]) is divided into two sides:
The left side shows the target status of the locking device ("Actual") –
i.e. the desired status configured in the LSM software.
The right side shows the locking device's current status ("Target") – i.e.
the status which was last programmed.
The following features can be enabled depending on the locking device
type:
Pulse length
This where you indicate the number of seconds for the duration of
switch pulse. The value can be set at 0.1 to 25.5 seconds. If you enter 3
seconds, for example, an electric strike is released for 3 seconds before
it locks again.
Access control
8. Configurations in the software
For SREL.ADV only
Autodetection
If an external antenna is
connected, this is the one which
is used. SmartRelay switches off
the internal antenna in such
cases. If no external antenna is
connected (standard case),
SmartRelay functions with the
internal antenna.
both active
SmartRelay is able to use both
antennas to verify transponder
bookings.