SREL, SREL.ADV, SREL.W SREL.G2, 1. Intended use SREL.G2.W, SREL2.G2 (Manual) 4 / 44 1 Intended use SimonsVoss SmartRelay is an electronic switch which can be activated with suitable ID media such as transponders . SmartRelay administration varies depending on the SmartRelay in question:...
SREL, SREL.ADV, SREL.W SREL.G2, 2. General safety instructions SREL.G2.W, SREL2.G2 (Manual) 5 / 44 2 General safety instructions Signal word (ANSI Possible immediate effects of non-compliance Z535.6) DANGER Death or serious injury (likely) WARNING Death or serious injury (possible, but unlikely)
Page 6
SREL, SREL.ADV, SREL.W SREL.G2, 2. General safety instructions SREL.G2.W, SREL2.G2 (Manual) 6 / 44 CAUTION Fire hazard posed by batteries The batteries used may pose a fire or burn hazard if handled incorrectly. 1. Do not try to charge, open, heat or burn the batteries.
Page 7
SREL, SREL.ADV, SREL.W SREL.G2, 2. General safety instructions SREL.G2.W, SREL2.G2 (Manual) 7 / 44 Operational malfunction due to radio interference This product may be affected by electromagnetic or magnetic interference. Do not mount or place the product directly next to devices that could cause electromagnetic ...
SREL, SREL.ADV, SREL.W SREL.G2, 3. Product specific safety instructions SREL.G2.W, SREL2.G2 (Manual) 8 / 44 3 Product specific safety instructions IMPORTANT Unauthorised access The relay in the controller can be short-circuited by unauthorised persons. Mount the controller with the relay in an environment that is protected against unauthorised ...
SREL, SREL.ADV, SREL.W SREL.G2, 4. Meaning of the text formatting SREL.G2.W, SREL2.G2 (Manual) 9 / 44 4 Meaning of the text formatting This documentation uses text formatting and design elements to facilitate understanding. The table explains the meaning of possible text formatting:...
SREL, SREL.ADV, SREL.W SREL.G2, 5. General SREL.G2.W, SREL2.G2 (Manual) 10 / 44 5 General 5.1 Versions SmartRelays are available in an extensive variety of versions for different product lines. Carefully check which SmartRelay is the right one for your use before placing an order.
Page 11
Authorised for up to 64,000 transponders Access control Extended connection op- tions Support for MIFARE & Des- fire cards Connection options for ex- ternal card readers SmartRelay The SREL provides simple yes/no authorisation for a maximum of 8,184 different transponders.
12 / 44 SmartRelay ZK Similar to the basic version (SREL), but with the option of access event logging connected separately for the last 1,024 accesses (firmware version 4.0.01.15 and higher) with date and time, or day-time zones for up to five user groups and automatic locking and unlocking.
A stable power supply is required to operate Digital SmartRelay 3063. Mains adapters are not included in the delivery package. Some SmartRelays can be operated using batteries (SREL.BAT) as an option. No additional power supply may be connected in such cases.
SREL, SREL.ADV, SREL.W SREL.G2, 5. General SREL.G2.W, SREL2.G2 (Manual) 15 / 44 5.5 More information All cabling used to connect SmartRelay should be type IY(ST)Y ..x0.6 – twisted pair, shielded cable – and should not exceed 100 m in length.
SREL, SREL.ADV, SREL.W SREL.G2, 6. Initial operation SREL.G2.W, SREL2.G2 (Manual) 16 / 44 6 Initial operation Check 1. Unpack SmartRelay and check for any damage. 2. Connect SmartRelay to a power supply or a battery. 3. Activate the SmartRelay with a transponder and test whether the SmartRelay responds to activation in some way or other.
SREL, SREL.ADV, SREL.W SREL.G2, 7. Connections SREL.G2.W, SREL2.G2 (Manual) 17 / 44 7 Connections 7.1 SREL SmartRelais Default G1 (SREL) Power supply unit Battery Relay Name Symbol Description Either positive terminal when connected to Power supply a direct current (5 to 24 VDC) or one of the...
Symbol Description Normally open contact in the relay NO relay changeover contact. This contact is closed against Relay COM when not connected 7.2 SREL.ADV, SREL.W, SREL.G2, SREL.W.G2 SmartRelais Advanced G1 (SREL.ADV) SmartRelais White G1 (SREL.W) SmartRelais G2 (SREL.G2) ...
NO relay changeover contact. This contact is closed against Relay COM when not connected External anten- BROWN Connection for colour-coded cables in an WHITE external antenna (order code: SREL.AV) GREEN brown/white/green/yellow GREY YELLOW RS-485COM RS-485A Bus connection for external modules RS-485-B Type 3.0 - 5.0 V +/- 0.5 V for external LED...
Page 20
SREL, SREL.ADV, SREL.W SREL.G2, 7. Connections SREL.G2.W, SREL2.G2 (Manual) 20 / 44 First of all, the SmartRelay reads the transponder data. If the transponder is authorised for use in the SmartRelay, these data are transmitted to the third-party system via the serial interface. You will receive detailed specifications for individual data formats from SimonsVoss Technologies GmbH.
Page 21
SREL, SREL.ADV, SREL.W SREL.G2, 7. Connections SREL.G2.W, SREL2.G2 (Manual) 21 / 44 External power supply unit Possible resistance to power limitation. The V+ output withstands max. 50 mA Max. Buzzer or LED...
Page 22
SREL, SREL.ADV, SREL.W SREL.G2, 7. Connections SREL.G2.W, SREL2.G2 (Manual) 22 / 44 7.2.1.2 OMRON External access control or time-and- attendance system Activation relay Pull-up resistances...
Page 23
SREL, SREL.ADV, SREL.W SREL.G2, 7. Connections SREL.G2.W, SREL2.G2 (Manual) 23 / 44 7.2.1.3 Wiegand interface External access control or time-and- attendance system Pull-up resistances 7.2.1.4 Kaba Benzing, Siemens, Gantner LEGIC, Primion and ISGUS interface External access control or time-and- attendance system...
SREL, SREL.ADV, SREL.W SREL.G2, 7. Connections SREL.G2.W, SREL2.G2 (Manual) 24 / 44 7.3 SREL2.G2.W SmartRelais 2 G2 White (SREL2.G2.W) Connection for LNI Connection for card readers External antennas Functions connections Power supply Relay Name Symbol Description Power supply Direct current 9 to 24 V DC...
SREL, SREL.ADV, SREL.W SREL.G2, 7. Connections SREL.G2.W, SREL2.G2 (Manual) 25 / 44 Name Symbol Description Functions con- Input ext. Trigger input (3-24 V DC nection 1 ext. contact must be isolated) Functions con- Omron data / Wiegand DO nection 2...
The SmartRelay's settings can be adjusted in the [Configuration/Data] tab in the locking device's properties. 8.1.1 SmartRelay (G1): SREL, SREL.ADV, SREL.W This tab ([Configuration/Data]) is divided into two sides: The left side shows the target status of the locking device ("Actual") –...
Page 27
SREL.G2.W, SREL2.G2 (Manual) 27 / 44 The following features can be enabled depending on the locking device type: Only possible in SREL.ZK and SREL.ADV versions. The 1,024 most Audit trail recent transponder transactions are logged with the date and time.
Page 28
8. Configurations in the software SREL.G2.W, SREL2.G2 (Manual) 28 / 44 For SREL.ZK and SREL.ADV only. A time zone plan needs to be up- loaded when the time switch-over is activated. This allows SmartRelay to remain unlocked during the indic- ated times (in Group 5).
Page 29
SmartRelays, for example. For SREL.ZK and SREL.ADV only: Normally, only authorised transpon- der operations are logged. You need Log unauthorised attempts to select this option if you also wish to record attempts to open the door with non-authorised transponders.
Page 30
SmartRelay. These modules are connected to the terminals RS-485 C OM, RS-485 A and RS-485 B. For SREL.ADV only: You can enter the type of card reader here which the SmartRelay is to simulate for operation as a serial interface.
SmartRelay is able to use both antennas to verify transponder bookings. 8.1.2 SmartRelay (G2): SREL.G2, SREL.W.G2, SREL2.G2 This tab ([Configuration/Data]) is divided into two sides: The left side shows the target status of the locking device ("Actual") – ...
Page 32
Time zone control Only possible in SREL.ZK and SREL.ADV versions. A time zone plan can be uploaded and the transponders are approved or blocked according to their time zone group. Logging unauthorised attempted access events ...
Page 33
SREL, SREL.ADV, SREL.W SREL.G2, 8. Configurations in the software SREL.G2.W, SREL2.G2 (Manual) 33 / 44 This option is enabled for all G2 SmartRelays as standard. The LSM first adds a data record for an active locking device and checks whether the locking device has an interface during programming.
SREL.G2.W, SREL2.G2 (Manual) 34 / 44 For SREL.ADV only: This indicates which external component group is connected. In flip-flop mode, SmartRelay emits a permanent signal when switched on if there is an external LED; if there is a beeper, an audible signal is only emitted when there is a change of status.
SREL.G2.W, SREL2.G2 (Manual) 35 / 44 9 Signalling SREL, SREL.ADV, SREL.W, SREL.G2, SREL.W.G2 LED lights up or flashes green: ID medium is authorised and the SREL activates. No response from the LED: ID medium rejected or not recognised. ...
10. Maintenance SREL.G2.W, SREL2.G2 (Manual) 36 / 44 10 Maintenance 10.1 Battery warning and battery replacement when SREL.BAT is used A SmartRelay can emit a battery warning as follows when the battery capacity is depleted: SREL, SREL.ZK and SREL.ADV ...
SRD (WaveNet) (de- 868.000 MHz - <25 mW ERP pending on equipment) 868.600 MHz There are no geographical restrictions within the EU. 11.1 Technical specifications SREL, SREL.ADV, SREL.W, SREL.G2, SREL.W.G2 Black housing: 72×57×25.5 Dimensions l×w×h in mm White housing (.W): 78×78×19 ...
Multi-function connections F1, F2, F3 Max. 24 V , max. 50 mA 15 G for 11 ms, 6 shocks as per IEC 68-2-27 Vibrations Not approved for use when subject to permanent vibrations 11.2 Drilling template SREL, SREL.ADV, SREL.G2 71,8 (Dimensions in mm)
SREL, SREL.ADV, SREL.W SREL.G2, 11. Technical specifications SREL.G2.W, SREL2.G2 (Manual) 40 / 44 Output relay type NO contact Output relay continuous current Max. 1.0 A Output relay switch-on current Max. 2.0 A Output relay switching voltage Max. 24 V Output relay switching power 10^6 activations at 30 VA Multi-function connections F1, F2, F3 Max.
12. Declaration of conformity SREL.G2.W, SREL2.G2 (Manual) 41 / 44 12 Declaration of conformity The company SimonsVoss Technologies GmbH hereby declares that article MK.SREL.ZK.G2, SREL.*, SREL.G2.*, (MK.)SREL2.* complies with the following guidelines: 2014/53/EU "Radio equipment" 2014/30/EU "EMC" 2011/65/EU "RoHS"...
Page 42
SimonsVoss website ( certificates.html Information on disposal Do not dispose the device (MK.SREL.ZK.G2, SREL.*, SREL.G2.*, (MK.)SREL2.*) in the household waste. Dispose of it at a collection point for electronic waste as per European Directive 2012/19/EU.
Page 43
SREL, SREL.ADV, SREL.W SREL.G2, 13. Help and other information SREL.G2.W, SREL2.G2 (Manual) 43 / 44 Address SimonsVoss Technologies GmbH Feringastrasse 4 85774 Unterföhring Germany...
Page 44
This is SimonsVoss SimonsVoss is a technology leader in digital locking systems. The pioneer in wirelessly controlled, cable-free locking technology delivers system solutions with an extensive product range for SOHOs, SMEs, major companies and public institutions. SimonsVoss locking systems unite intelligent functions, optimum quality and award-winning German-made design.