STOPPING ENGINE
Stop the engine in the following procedures.
1. Lower the bucket before stopping the engine.
2. Run the engine at slow idle speed for 5 minutes to cool
the engine.
IMPORTANT: If the engine equipped with a turbocharger
is stopped without first performing the cool
down operation, the lubricant on the turbo-
charger bearing surfaces may desiccate due
to the intense heat present inside the tur-
bocharger, possibly causing damage to the
turbocharger.
3. Turn the key switch (1) to OFF position (2) to stop the en-
gine.
4. Pull front control lever lock (3) to the LOCK position (4).