FUSE BOX
IMPORTANT: If a fuse blows, turn the key switch OFF. After
checking and correcting the cause of the
trouble, replace the fuse with a new one.
The fuses function as a safety valve to prevent excess current
from flowing in the electrical system. Slow blow fuses (1, 2, 3,
and 4) are used. Each fuse capacity varies depending on its
corresponding circuit. Be sure to replace the blown fuses only
with the specified ones. When checking fuses, check the slow
blow fuses and (1 and 2) and fuses A and B in this order..
ZW180:
1- 120A
2- 65A
ZW220/ZW250: 1- 100A
2- 65A
ZX310:
1- 120A
2- 65A
OPERATOR'S STATION
a-Side
1-69
Front Attachment
b-Side
Fuse Boxes
A 30A-fuse is provided on
the ZW180, ZW220 and 250.
Fuse Box A
Fuse Box B
1
2
ZW180, ZW220, ZW250
3
ZW310
Relay Boxes
M4GB-01-107
M4GB-01-108
M4GB-01-109
4
M4GB-01-110