Clarke CSG1C Operation & Maintenance Instructions Manual page 7

Air stapler
Table of Contents

Advertisement

• The minimum hose diameter should be 5/16"(8mm) ID and fittings
should have the same internal dimensions.
• Never exceed the maximum operating pressure for the tool. It is
recommended that air pressure to this tool does not exceed 90 psi
at the tool when running. Higher pressures and unclean air will
shorten the life of the tool due to faster wear and is a possible safety
hazard.
• Tools of this type operate on a wide range of air pressures. It is
recommended that air pressure be set to between 60 and 100psi. at
the tool when running.
• The air inlet used for connecting air supply, is a 10mm Quick Fit type.
• If required, connect an in-line mini oiler to the tool. A mini oiler helps
to prolong the life of the air tool.
• If a mini-oiler is not being used, run a few drops of oil through the tool
before use. It can be entered through the air inlet.
• Connect a suitable hose to the female air inlet.
• Connect the other end of the hose to the air supply.
• Turn on the air supply and check for air leaks. Rectify any found
before proceeding.
Your air tool is now ready for use.
You can fit a whip hose with a quick fit coupling if required (available from
your Clarke dealer.).
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

3110375

Table of Contents