Technical Data; Indicators And Operating Elements - Pepperl+Fuchs 2-D LiDAR R2000 Series Manual

Measuring sensors
Hide thumbs Also See for 2-D LiDAR R2000 Series:
Table of Contents

Advertisement

2-D LiDAR Sensor
Product Description
Note
Influence of ambient conditions
The speed of light depends on the air temperature and barometric pressure.
The influence of the air temperature is 1 ppm/K.
The influence of the barometric pressure is -0.3 ppm/hPa.
The user must take these faults into consideration when measuring long
distances.
In the operating range of -10 °C ... +50 °C, this fault amounts to 0.6 mm at a
distance of 10 m.
3.4

Technical Data

The technical data for this product can be found in the datasheet at www.pepperl-
fuchs.com.
3.5

Indicators and Operating Elements

7
6
5
Figure 3.1
No.
1
2
3
4
5
6
7
8
9
Table 3.1
1
2
3
4
Indicators and Controls
Description
Operating indicator
Fault indicator
"Next" menu button
"Return" menu button
"Q2" signal indicator
"Q1" signal indicator
Laser beam outlet
Ethernet link indicator
Ethernet activity indicator