8.
Safety
Destination : All over the world
●
Applicable standards : UL60950/C-UL/EN60950
●
Unit class : Class I units (the units protected against electric shocks by protective grounding, or those
●
equipped with 3-core power cords)
Ratings : AC100 - 240V 50/60Hz 1.3-0.7A
●
8.1
Insulation Resistance Test
An insulation resistance should be measured under the conditions specified below, in order to confirm
that the requirements of the judgment standard are met.
1) Measuring conditions
Measuring instrument : 500V DC MEGOHM Meter
●
Testing point : Between the power circuit block and the exposed metallic block
●
Measured value readout : A test voltage should be applied for one minute and the resistance
●
2) Judgment standard:
The resistance of the insulation between the power terminal and the ground contact is more
than 10M ohms while withstanding a voltage of 500Vdc.
8.2
Dielectric Strength Test
To confirm the freedom from insulation breakdown, testing should be carried out under the conditions
specified below.
1) Measuring conditions
Measuring instrument: Dielectric strength tester (The specified voltage should be maintained in the
●
state that a current of 10mA is carried.)
Testing point: Between the electrical circuit block and the exposed metallic block (D-SUB
●
connector)
Note : The electrical circuit block should mean the power input block (primary side). Testing should
be carried out under the condition that both poles of the power plug are short-circuited. (Where
a 3-core cord is used, the two poles other than the ground terminal should be short-circuited.)
2) Judgment standard
There is no breakdown of the insulators or short circuits when applying an alternating potential of
1000Vac for a duration of 1(one) minute or 1500Vac for a duration of 2(two) second at 50Hz
between the metallic chassis and the input power supply active and neutral terminals connected
together.
(D-SUB connector)
value should be read out thereafter.
5-20
Need help?
Do you have a question about the MultiSync 20WGX2 Series and is the answer not in the manual?
Questions and answers