Commissioning
6.4 Modbus address register
Energy counters
Modbus measured variables with the function codes 03 and 04
Address
Number
of regis-
Hex
Decimal
ters
1B20
6944
4
1B24
6948
4
1B28
6952
4
1B2C
6956
4
1B30
6960
4
1B34
6964
4
1B38
6968
4
1B3C
6972
4
1B40
6976
4
1B44
6980
4
1B48
6984
4
1B4C
6988
4
1B50
6992
4
1B54
6996
4
1B58
7000
4
1B5C
7004
4
1B60
7008
4
1B64
7012
4
1B68
7016
4
1B6C
7020
4
Address
Number
of regis-
Hex
Decimal
ters
1B98
7064
4
1B9C
7068
4
1BA0
7072
4
1BA4
7076
4
1BA8
7080
4
1BAC
7084
4
1BB0
7088
4
1BB4
7092
4
1BB8
7096
4
1BBC
7100
4
1BC0
7104
4
1BC4
7108
4
1BC8
7112
4
1BCC
7116
4
1BD0
7120
4
1BD4
7124
4
86
Format
Access
Unit
UINT64
R
Wh
UINT64
R
Wh
UINT64
R
varh
UINT64
R
varh
UINT64
R
VAh
UINT64
R
Wh
UINT64
R
Wh
UINT64
R
varh
UINT64
R
varh
UINT64
R
VAh
UINT64
R
Wh
UINT64
R
Wh
UINT64
R
varh
UINT64
R
varh
UINT64
R
VAh
UINT64
R
Wh
UINT64
R
Wh
UINT64
R
varh
UINT64
R
varh
UINT64
R
VAh
Format
Access
Unit
UINT64
R
Wh
UINT64
R
Wh
UINT64
R
varh
UINT64
R
varh
UINT64
R
VAh
UINT64
R
Wh
UINT64
R
Wh
UINT64
R
varh
UINT64
R
varh
UINT64
R
VAh
UINT64
R
Wh
UINT64
R
Wh
UINT64
R
varh
UINT64
R
varh
UINT64
R
VAh
UINT64
R
Wh
Factor
Measured variable
10.0
Total active energy - Import
10.0
Total active energy - Export
10.0
Total reactive energy - Import
10.0
Total reactive energy - Export
10.0
Total apparent energy
10.0
Partial active energy - Import
10.0
Partial active energy - Export
10.0
Partial reactive energy - Import
10.0
Partial reactive energy - Export
10.0
Partial apparent energy
10.0
T1 Active energy - Import
10.0
T1 Active energy - Export
10.0
T1 Reactive energy - Import
10.0
T1 Reactive energy - Export
10.0
T1 Apparent energy
10.0
T2 Active energy - Export
10.0
T2 Active energy - Export
10.0
T2 Reactive energy - Import
10.0
T2 Reactive energy - Export
10.0
T2 Apparent energy
Factor
Measured variable
10.0
T1 Active energy L1 - Import
10.0
T1 Active energy L1 - Export
10.0
T1 Reactive energy L1 - Import
10.0
T1 Reactive energy L1 - Export
10.0
T1 Apparent energy L1
10.0
T2 Active energy L1 - Import
10.0
T2 Active energy L1 - Export
10.0
T2 Reactive energy L1 - Import
10.0
T2 Reactive energy L1 - Export
10.0
T2 Apparent energy L1
10.0
T1 Active energy L2 - Import
10.0
T1 Active energy L2 - Export
10.0
T1 Reactive energy L2 - Import
10.0
T1 Reactive energy L2 - Export
10.0
T2 Active energy L2 - Import
10.0
T2 Active energy L2 - Export