AUMA AUMATIC AC 01.1 Short Instructions page 8

Actuator controls, profibus dp
Hide thumbs Also See for AUMATIC AC 01.1:
Table of Contents

Advertisement

Actuator controls AUMATIC AC 01.1 / ACExC 01.1
Profibus DP
Figure D-4: Bus connection for channel 1
(Standard)
Another bus station follows the actuator
B
A
from the previous
Profibus DP device
channel 1
Actuator is the final bus station
B
A
Table 4: Technical data Ex-plug/ socket connector with terminal board for explosion-proof actuators
Technical data
No. of contacts max.
Marking
Voltage max.
Current max.
Type of customer connection
Cross section max.
Material: Pin / socket carrier
Contacts
1) Suitable for copper wires. For aluminium wires contact AUMA.
8
31
32
To the next
Profibus DP device
channel 1
31
32
34
Motor power connections
3
U1, V1, W1
550 V
25 A
Screws
6 mm
2
Araldite / Polyamide
Brass (Ms)
Figure D-5: Bus connection for channel 2
(component redundancy only)
Another bus station follows the actuator
B
B
A
A
from the previous
Profibus DP device
channel 2
Actuator is the final bus station
33
B
A
1)
Protective earth
1 (leading contact)
according to VDE
Screws
6 mm
2
Araldite / Polyamide
Brass (Ms)
Short instructions
35
36
to the next
Profibus DP device
channel 2
35
36
38
Control pins
38 pins / sockets
1 to 24, 31 to 50
250 V
10 A
Screws
1.5 mm
2
Araldite / Polyamide
Brass (Ms) tin-plated
B
A
37

Advertisement