Configure the Adapter for Direct Connection in RSLogix 5000 Software
The 1734-AENT adapter appears in the Ethernet folder.

Add the POINT I/O Modules to the I/O Configuration

You now add POINT I/O modules to the I/O Configuration List under the
1734-AENT adapter.
In this example, you add a 1734-OW2 relay output and a 1734-OV4E sink
output module with standard configurations. Use these steps as a guide when
configuring different I/O modules for your system.
This example application uses the I/O modules default
TIP
configurations. For more information, see the POINT I/O
Selection Guide, publication 1734-SG001.

Add the Relay Output Module

1. Right-click the remote 1734-AENT adapter under the I/O
Configuration folder and select New Module.
Publication 1734-UM011D-EN-P - May 2011
33