Hose Lines / Pipework; Suction Line - ProMinent vonTaine 1010 PP Assembly And Operating Instructions Manual

Solenoid-coupled centrifugal pump
Table of Contents

Advertisement

Arrangement/Installation

4.2 Hose Lines / Pipework

4.2.1 Suction Line

14
3.
Fix the pump onto a sufficiently load-bearing base surface.
Provide the fittings on site.
CAUTION!
Pressure surges can destroy the pump housing.
Never use quick-closing valves in the pipework.
3
2
Fig. 5: Pump suction and pressure nozzles
1
Suction nozzle
2
Sealing rings provided
3
Pressure nozzle
1.
Use pipework widths to match the pump's suction and pres‐
sure nozzles.
Weight of the lines
The weight of the lines may not exert a load on the
pump housing.
2.
Lead the suction and discharge lines without tension to the
pump housing.
It is the duty of the operator of the pump to ensure that the connec‐
tions to the suction and pressure nozzles are properly established.
Use pipe or hose material as the suction line, which cannot
n
deform from the negative pressure that occurs, not even at
high temperatures.
You have to keep the suction line as short as possible and fit it
n
so that no gases can accumulate. Always route the suction line
falling towards the pump.
1
A2452