GUID
Domain
Interface Configuration
Card Firmware/Software
Version
Reset to Defaults on Restart
PTP - An Overview
PTP provides a mechanism for distributing a common reference clock throughout the system.
Each device maintains an internal clock that is synchronized to this common reference clock.
RTP timestamps within the RTP packet header (and extended header) are used for
synchronization.
Synchronization across multiple essence streams is achieved by comparing the offset between
the RTP timestamp and clock.

Setting Spigot Configuration

IMPORTANT!
Existing details must be cleared down before establishing a new
configuration. Failure to do this may result in unexpected behavior
from the module.
To set a new spigot configuration, follow these steps:
1 From the Configuration page, select the required software from the Software Version
pane, then select the firmware which provides the required combination of inputs, outputs
and flow standards from the list displayed on the Card Firmware>New pane.
Note that Restore and Restart buttons are displayed only when an item not currently
installed is selected.
2 Enable the Reset to Defaults on Restart checkbox. This will cause existing details stored
on the module, other than network IP settings, to be cleared down prior to restarting the
module. See
Defaults
3 Click Restart to restart the module and implement any changes made.
Operation
Displays the absolute unique identifier associated with the
module.
RollCall+ uses domains to partition a network; only nodes on
the same domain can communicate with one another. A
domain is uniquely identified with a number and a friendly
name/alias.
Set an ID as required, then press Take to confirm the change.
Displays the IP address for each Ethernet interface.
Each software version contains multiple firmware images.
These allow different spigot input/output and flow standard
combinations to be selected. See
Configuration, below, for more information.
Enable checkbox to cause any existing details stored on the
module, other than network IP settings, to be cleared down
prior to restarting the module. See
Configuration, below, and
information.
on page 92 for more information.