Epson LS20 Series Manipulator Manual page 171

Scara robot
Hide thumbs Also See for LS20 Series:
Table of Contents

Advertisement

LS20 Rev.4
0 pulse position of Joint #2:
position where Arms #1 and #2
are in a straight line
(Regardless of the Joint #1
direction.)
0 pulse position of Joint #3:
upper limit position in motion
range
The height of Joint #3 depends on manipulator model.
LS20-804S, LS20-A04S
0 pulse position of Joint #4:
position where the flat surface of the shaft (or
the set screw of the bottom mechanical stop)
faces toward the tip of Arm #2.
(3)-3 Connect EPSON RC+ to the Controller.
Select a robot to be calibrated. Input as below in the [Command Window] and
execute it.
(This example uses "robot 1".)
> robot 1
Maintenance 13. Calibration
0 pulse
+
LS20-804C, LS20-A04C
+
0 pulse
Set Screws
Flat Surface
159

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents