FLIR Quasar CP-6408-21-I Installation And User Manual page 32

22x / 31x 4k ir ptz cameras
Hide thumbs Also See for Quasar CP-6408-21-I:
Table of Contents

Advertisement

Installation
2. Open the
I/O Devices
Page.
3. Select local output 1.
4. Make sure the following local output 1 default settings are
specified:
Setting
Value
State
Off
Idle State
Open
Reset Interval
0 seconds (automatic output pin reset
is disabled)
Testing the washer and wiper
Before testing the washer and wiper, make sure you:
·
Install the wash kit according to the kit's instructions manual and according to the instructions above.
·
Fill the washer liquid tank.
1. Using the camera's web page, open the Wiper page.
2. Under Washer device installed, click On. To apply the change
to this setting, the camera needs to reboot. After the camera
reboots, log back in and open the Wiper page.
3. Set the washer position.
Click Advanced Settings.
Under Washer Position, use the PTZ controls to move the
camera into a position so that the washer sprays liquid over the
camera lens window.
Click Set. The camera saves its current pan and tilt position as
the washer position.
You can also specify a wash spray duration between 0-10
seconds.
4. Activate the washer.
Under Washer, click Start. Make sure the washer activates.
Important
If the initial washer position does not spray liquid over the camera lens window, reset the washer
position and try again.
2. Activate the wiper.
CP-6408 Range Installation and User Guide - Revision 120 - September 2020
This document does not contain any export-controlled inf ormation.
27