Circuit Example For The Control Circuit; Figure 12: Circuit Example For The Control Circuit - KEB COMBIVERT F5 Series Instructions For Use Manual

Installation active infeed controller
Hide thumbs Also See for COMBIVERT F5 Series:
Table of Contents

Advertisement

CONNECTION OF THE COMbIVERT F5-AIC

6.6.5 Circuit example for the control circuit

1
2
1
2
1
3
4
3
4
3
5
6
5
6
5
11
12
11
12
21
22
13
14
-K1
14
-K5
12
14
-K3
-K2
12
22
A1
A1
-K2
-K3
-K4
A2
A2
L
N
Legend
K1
Coupling relay (control on/off)
K2
Pre-charging contactor
K3 / K4 Main contactor
Coupling relay (max. 50 mA) for main
K5
contactor
S1
External control release
G2
24 V DC supply (recommended)
Figure 12:
Circuit example for the control circuit
2
13
14
4
6
X2A
-K2
12
-K3
14
A1
A1
-K1
A2
A2
ST
I1
+
-
24Vdc
-S1
14
-S2
14
U5
U6
14
11
12
-U5
A1
-K5
A2
RST
Uin
0V
+
-S3
14
-G2
S2
Second setpoint (customer)
S3
Error reset
S4
External release for drive converter
COMBIVERT F5-AIC
Drive converter
-U6
X2A
ST
Uout
-S4
14
47