KEB COMBIVERT F5 Series Instructions For Use Manual page 29

Installation active infeed controller
Hide thumbs Also See for COMBIVERT F5 Series:
Table of Contents

Advertisement

UNIT DATA
Device size
Housing size
Cooling mode (L=air; W=water)
Number of modules for master/slave
Input data
Mains phases
Permitted mains forms
Rated input voltage
Input voltage range
Mains frequency
Rated input power
Rated input current
Max. permissible mains fuse type gR / aR
Output data
Rated output voltage
Output voltage range
Overvoltage switch-off (E.OP)
Power supply/regenerative rated current
Max. regenerative DC current 30 s
Rated switching frequency
Max. switching frequency
Other data (referring to the rated data)
Overcurrent cut-off (E.OC)
Overload current (E.OL) 30 s
Max. permissible DC link capacity
Max. AIC charging current (=> 6.5)
Max. external charging current (=> 6.5)
Max. permissible total charging current (=> 6.5)
Mains input circuit (=> 6.5)
Permissible DC fuses
Short-circuit factor at the connection point (S
Power dissipation at rated operation
Max. heat sink temperature
The input current of the drive convertermust be limited to the rated current of the AIC / LCL filter, if
1)
necessary.
The operation is dependent on the voltage setpoint and the U
2)
Measured at a reference voltage of 680 V DC.
3)
Limited by the rated current of the DC-terminal ! The input current must be limited to 300 A for input
4)
voltages < 400 V.
Must be set to 4 kHz for AIC operation (factory setting 2 kHz) !
5)
Option precharging resistor =>
6)
Special settings are required for this device sizes (Reduction of the max. heat sink temperature
7)
to 85°C, =>
Programming
/ V
U
N
U
/ V
in
/ Hz
f
N
/ kVA
S
N
I
/ A
N
U
/ V
outN_dc
/ V
U
2)
_dc
/ V
U
OP_dc
I
/ A
3)
outN_dc
/ A
I
out_max_dc
f
/ kHz
SN
/ kHz
f
S_max
/ %
I
OC
/ %
I
OL
C
/ mF
ext
/ A
I
AIC
/ A
I
ext
I
/ A
pre
Type
/ S
)
kn
N
/ W
P
BR
/ °C
t
_max
„Additional precharging resistor at master-slave
manual).
30
33
34
P
P
P
L
L
W
2
3
3
TN system
400
340...480 ± 0%
50 / 60 ± 2
395
554
616
2 x 285
3 x 267
2 x 445
2 x 400
3 x 350
2 x 630
680
530...840
840
570
800
890
712
1000
1112
4
4
4
5)
5)
4
4
150
150
150
125
125
125
150
250
150
6)
6)
98
145
98
6)
6)
-
-
98
145
98
6)
6)
D1
=>
„DC fuses"
10 < S
" / < 350
kn
4700
6900
7400
90
90
90
7)
7)
limit (=>
Programming
OP
38
P
W
2
3
1005
3 x 483
3 x 630
1450
1813
4
5)
5)
4
4
150
125
250
6)
6)
146
6)
6)
-
-
146
6)
6)
12000
90
7)
7)
manual).
operation".
29

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COMBIVERT F5 Series and is the answer not in the manual?

Table of Contents

Save PDF