UNIT DATA
Device size
Housing size
Cooling mode (L=air; W=water)
Number of modules for master/slave
Input data
Mains phases
Permitted mains forms
Rated input voltage
Input voltage range
Mains frequency
Rated input power
Rated input current
Max. permissible mains fuse type gR / aR
Output data
Rated output voltage
Output voltage range
Overvoltage switch-off (E.OP)
Power supply/regenerative rated current
Max. regenerative DC current 30 s
Rated switching frequency
Max. switching frequency
Other data (referring to the rated data)
Overcurrent cut-off (E.OC)
Overload current (E.OL) 30 s
Max. permissible DC link capacity
Max. AIC charging current (=> 6.5)
Max. external charging current (=> 6.5)
Max. permissible total charging current (=> 6.5)
Mains input circuit (=> 6.5)
Permissible DC fuses
Short-circuit factor at the connection point (S
Power dissipation at rated operation
Max. heat sink temperature
The input current of the drive convertermust be limited to the rated current of the AIC / LCL filter, if
1)
necessary.
The operation is dependent on the voltage setpoint and the U
2)
Measured at a reference voltage of 680 V DC.
3)
Limited by the rated current of the DC-terminal ! The input current must be limited to 300 A for input
4)
voltages < 400 V.
Must be set to 4 kHz for AIC operation (factory setting 2 kHz) !
5)
Special settings are required for this device sizes (Reduction of the max. heat sink temperature to
6)
85°C, =>
Programming
Max. ambient temperature T
7)
28
/ V
U
N
U
/ V
in
/ Hz
f
N
/ kVA
S
N
I
/ A
N
U
/ V
outN_dc
/ V
U
2)
_dc
/ V
U
OP_dc
I
/ A
3)
outN_dc
/ A
I
out_max_dc
f
/ kHz
SN
/ kHz
f
S_max
/ %
I
OC
/ %
I
OL
C
/ mF
ext
/ A
I
AIC
/ A
I
ext
I
/ A
pre
Type
/ S
)
kn
N
P
/ W
BR
/ °C
t
_max
manual).
of 35°C.
a
24
26
27
U
U
U
L
L
W
L W
3
TN system
400
340...480 ± 0%
50 / 60 ± 2
125
173
208
180
250
300
250
350
400
680
530...840
840
180
250
300
270
313
375
8
4
8
8
8
8
180
150
150
150
125
125
45
43
40
226
226
226
226
226
226
D1
=>
„DC fuses"
15 < S
" / < 350
kn
2230
2550
3500
4500
90
90
60
90 60 90
limit (=>
Programming
OP
28
29
P
P
L
W
256
319
370
460
1)
500
630
370
460
4)
462
575
8
4
4
5)
5)
8
4
4
150
150
125
125
35
35
98
98
98
98
D1
10 < S
" /
kn
< 350
3000
3800
90
6) 7)
6)