Camozzi D Series Instruction Manual

Multipole size 1
Hide thumbs Also See for D Series:

Advertisement

Quick Links

The products are in compliance with the provisions of the following directives:
- 2004/108 / EC
They respond in full or only to the parts applicable to the following standards:
-
- CEI EN 61131-2
The EC Declarations of Conformity can be downloaded from
http://catalogue.camozzi.com/Downloads.aspx?cat=19
Instruction manual

Series D multipole size 1

1
5000026173
Version 00
Made in Italy

Advertisement

Table of Contents
loading

Summary of Contents for Camozzi D Series

  • Page 1: Series D Multipole Size

    The products are in compliance with the provisions of the following directives: - 2004/108 / EC They respond in full or only to the parts applicable to the following standards: - CEI EN 61131-2 The EC Declarations of Conformity can be downloaded from http://catalogue.camozzi.com/Downloads.aspx?cat=19...
  • Page 2 5000026173 Instruction manual Series D multipole size 1 Version 00...
  • Page 3: Table Of Contents

    5000026173 Instruction manual Series D multipole size 1 Version 00 Summary Product identification ........................ 5 ................................. 5 General recommendation ......................6 General characteristics and conditions of use ................7 Product storage and transport ....................8 System description ........................8 Installation and commissioning ....................8 Connecting and signaling elements ..........................
  • Page 4 5000026173 Instruction manual Series D multipole size 1 Version 00 USE LIMITATION ........................26 MAINTENANCE ........................26 ECOLOGICAL INFORMATION ....................26 Contacts ..........................27 Product Certification ........................27 Technical assistance ........................27...
  • Page 5: Product Identification

    5000026173 Instruction manual Series D multipole size 1 Version 00 1. Product identification...
  • Page 6: General Recommendation

    • The product can be put into operation only in compliance with the specifications indicated, if these specifications are not respected the product can be put into operation only after authorization by Camozzi. • Avoid covering the appliances with paints or other substances that reduce heat dissipation.
  • Page 7: General Characteristics And Conditions Of Use

    5000026173 Instruction manual Series D multipole size 1 Version 00 3. General characteristics and conditions of use PNEUMATIC Valve type Spool with seals 5/2 monostable e bistable Valve functions 2x3/2 NC 2x3/2 NO 1x3/2 NC+1x3/2 NO 5/3 CC – CP – CO spool: AL - spool seals: HNBR - other seals: NBR - metal body - Material technopolymer bottoms and sub-base...
  • Page 8: Product Storage And Transport

    The detected data, alarms and health status can be transmitted via cable to a PLC or via WLAN to an IIoT Gateway for subsequent sending to the Cloud. The D Series is suitable for use in applications with limited installation space without penalizing the flow rate.
  • Page 9: Connecting And Signaling Elements

    5000026173 Instruction manual Series D multipole size 1 Version 00 If the device is used to operate an actuator whose accidental movement can generate a hazard,  provide for appropriate locking devices for the moving part of the actuator. Make sure the connectors are connected and fastened correctly. ...
  • Page 10: Electrical Connection

    5000026173 Instruction manual Series D multipole size 1 Version 00 Electrical connection 25 poles Pin Cables Color G25X1 Function 44 poles Pin Cables Color G44X1 Elettrovalvola - Bobina WHITE V1 – 14 WHITE V1 – 14 BROWN V1 – 12 BROWN V1 –...
  • Page 11: Electrical Characteristics

    44-pole connector. The multipolar D Series has a digital output (Pin 23 of the D-sub 25-pole connector or pin 40 of the D-sub 44- pole "open collector" diagnostic connector, the connection of the diagnostic output is optional 6.4 Adding a valve position or changing their position.
  • Page 12 5000026173 Instruction manual Series D multipole size 1 Version 00 6.5 Procedure for numbering the sub-bases / valve positions The numbering procedure must be carried out in all those cases in which the sub-bases are added, removed or moved To proceed with the numbering of the valve positions it is necessary to: to.
  • Page 13: Wlan Connection Procedure

    The island is configured as an Access Point and generates the "CamozziWiFi" WLAN network. e. Using a PC or portable device, connect to the "CamozziWIFI" network, access with the password "!! camozzi" Open a browser and connect to the address 192.168.1.1, where the following page (mini-app)
  • Page 14: Coilvision. Description Of The Predictive Diagnostic System And Data Collection

    COILVISION. DESCRIPTION OF THE PREDICTIVE DIAGNOSTIC SYSTEM AND DATA COLLECTION The D Series valve island is able to send data, alarms and the health status of individual solenoid pilots via WLAN, allowing them to be monitored and predicted for wear and efficiency.
  • Page 15: Camozziuvix: Series D Configuration

    5000026173 Instruction manual Series D multipole size 1 Version 00 The information on the health status of the individual solenoid valves mounted on the island is displayed by means of a gauge indicator with decreasing percentage based on a predictive algorithm. 7.
  • Page 16: Assignment Of The Name And Group To The Series D Valve Island

    5000026173 Instruction manual Series D multipole size 1 Version 00 7.2 : Assignment of the name and group to the Series D valve island The system signals the presence of a new Series D island connected to the WLAN network click on the icon (1) to display the Serial number of the Series D island.
  • Page 17 5000026173 Instruction manual Series D multipole size 1 Version 00 NOTE: Instructions for creating a Device Group (from file: 5000024829 - User manual UVIX.pdf) Click on the Setup icon and select the "Devices Group" item Devices Groups: it is possible to add new device groups by specifying their name, or view and / or ...
  • Page 18 5000026173 Instruction manual Series D multipole size 1 Version 00 Once the button [1] has been pressed, the following screen will be displayed: Figura 14 – Devices group After entering the required information (the mandatory ones are indicated with "*"), you can conclude the insertion of the new group of devices by clicking on the "Save"...
  • Page 19: General Information And Valve Island Status

    5000026173 Instruction manual Series D multipole size 1 Version 00 7.3: General information and valve island status The connected Series D valve island is displayed in the list of devices (6) on the left side of the screen. Click on the name to view the relative screen with general information (7), the status of the island (8), the "tabs" (9) for viewing: - Temperature and supply voltage of the Series D island - the status of the valve island alarms (see chapter "8.
  • Page 20: End Manual Mode

    5000026173 Instruction manual Series D multipole size 1 Version 00 The valve island switches to manual mode (11) and the controls (12) appear on the screen 7.4.1 End manual mode: returns the valve island to the "automatic" state 7.4.2 Reset slave info: resets the state of health and the number of cycles performed by the valve which is mounted on a sub-base (see paragraph 7.5) Click on the "Send"...
  • Page 21: Set Digital Output: Allows Remote Operation Of The Single Coil Of The Valve Island

    5000026173 Instruction manual Series D multipole size 1 Version 00 7.4.3 Set Digital Output: allows remote operation of the single coil of the valve island. Warning: make sure that the solenoid valves are activated in total safety In this mode the controls and commands of the PLC or control system are deactivated Click on the "On"...
  • Page 22: Configurazione Dei Parametri Della Sottobase (Solo Con Accesso "User")

    5000026173 Instruction manual Series D multipole size 1 Version 00 7.6 Configurazione dei parametri della sottobase (solo con accesso “user”) La configurazione dei parametri è possibile solo con l’isola di valvola in modalità manuale. Cliccare sul tasto “Configuration” (18) (presente solo con accesso “user”) per entrare nella schermata di configurazione della singola sottobase/valvola.
  • Page 23: Set Alarms Enable: Enabling Of The Single Alarm For Each Valve Position

    5000026173 Instruction manual Series D multipole size 1 Version 00 7.6.1 Set Alarms Enable: Enabling of the single alarm for each valve position By clicking on the drop-down menu (25) it is possible to enable or disable the single alarm for the sub-base in configuration.
  • Page 24: Fault Identification

    5000026173 Instruction manual Series D multipole size 1 Version 00 8. FAULT IDENTIFICATION The Series D valve island has an OPEN COLLECTOR diagnostic output with which it signals the faults that may occur to the single valve / sub-base. The maximum controllable current is 50mA and is equipped with short circuit protection.
  • Page 25 5000026173 Instruction manual Series D multipole size 1 Version 00 COMPORTAMENTO LED MASTER: STATO COMPORTAMENTO SIGNIFICATO (red) ● The valves island is in work status Work and the WLAN module (optional) is connection is NOT present or NOT (WLAN OFF) Blinking connected ●...
  • Page 26: Use

     Always make sure that you are wearing the correct safety equipment required by local authorities and by current laws.  In case of maintenance, replacement of wear parts, use only original Camozzi kits and have the operation carried out only by authorized specialist personnel. Otherwise the product homologation loses all its validity.
  • Page 27: Contacts

    5000026173 Instruction manual Series D multipole size 1 Version 00 13. Contacts Camozzi Automation SpA Società Unipersonale Via Eritrea, 20/I 25126 Brescia - Italy Tel. +39 030 37921 Fax +39 030 2400464 info@camozzi.com www.camozzi.com Product Certification National and International Directives, Regulations and Standards productcertification@camozzi.com...