7.6.1 Set Alarms Enable: Enabling of the single alarm for each valve position

25
By clicking on the drop-down menu (25) it is possible to enable or disable the single alarm for the sub-base in
configuration. If one of the events for which the alarm has been enabled occurs, an error message is sent.
The selectable alarms are:
- Non energized solenoid.
- Solenoid interrupted.
- Solenoid with anomalous current absorption or with excessive temperature.
Alarms are enabled by default.

6.5.1 Alarm mode:

26
For the single valve position it is possible to set the group of alarms as:
- Blocking (Default): the solenoid pilot in error is turned off and can no longer be piloted until the fault has
been removed.
- Non-blocking: it is possible to set the single valve position so that the error generated by the solenoid pilot is
signaled but the alarm is not blocking for the valve that will continue to operate.
NOTE: the system indicates with the icon (26) that the setting of the parameter in CamozziUVIX does not
correspond to the state physically set in the sub-base