6.5 Procedure for numbering the sub-bases / valve positions
The numbering procedure must be carried out in all those cases in which the sub-bases are added, removed
or moved
2
3
1
To proceed with the numbering of the valve positions it is necessary to:
to. Disconnect the power supply
b. Remove the cap that covers the Reset button (1)
c. Using a thin tip screwdriver, press and hold the Reset button
d. Switch on the power and keep the Reset button pressed for 3 seconds
is. Replace the cap that covers the Reset button (1)
Successful numbering is signaled by the simultaneous flashing of the LEDs on the sub-bases and the LED
operating status (2)
Otherwise, that is, if the numbering was not correctly done, the red diagnostic LED (3) will light up, and the
LED of the last valve position correctly numbered.