8. FAULT IDENTIFICATION

The Series D valve island has an OPEN COLLECTOR diagnostic output with which it signals the faults that may
occur to the single valve / sub-base. The maximum controllable current is 50mA and is equipped with short
circuit protection.
(Pin 23 of the 25-pin D-sub connector and Pin 39 of the 44-pin D-sub connector)
- Non energized solenoid.
- Solenoid interrupted.
- Solenoid with anomalous current absorption or with excessive temperature.
The status of this output depends on the type of alarm set:
Blocker (Default): the status of the diagnostic output is restored by removing the fault by turning the island off
and on again.
Non-blocking: the status of the diagnostic output is restored by removing the fault or by driving OFF the
solenoid that caused the problem
The sub-bases indicate the type of alarm by means of a coded flashing of the LED associated with the individual
solenoid pilot (see following table).
COMPORTAMENTO LED SOTTOBASI
STATO
Solenoid Not
(Yellow)
Energized
Solenoid
(Yellow)
Interrupted
Solenoid
Overcurrent or
(Yellow)
Overheating
Subbase
(Yellow)
Overheating
Instruction manual
Series D multipole size 1
LED
COMPORTAMENTO
Blinking
(1 blink @10 Hz every 1 s)
Blinking
(2 blink @10 Hz every 1 s)
Blinking
(3 blink @10 Hz every 1 s)
Blinking
(10 Hz)
The solenoid is not energized.
The solenoid is interrupted (open
circuit).
The solenoid is over the current
threshold or it is over the heating
threshold.
The subbase is over the heating
threshold.
24
5000026173
Version 00
SIGNIFICATO