Esd Wrist Strap; Environmental Requirements; Space And Airflow Requirements - Huawei TaiShan 200 23280 User Manual

Table of Contents

Advertisement

TaiShan 200 Server (Model 2280)
User Guide

5.3.2 ESD Wrist Strap

A cabinet or chassis is properly grounded.
Step 1 Put on the ESD wrist strap. See
Figure 5-2 Wearing an ESD wrist strap
Step 2 Tighten the ESD wrist strap to ensure that it is in good contact with your bare
skin.
Step 3 Insert the ground terminal of the ESD wrist strap into the ESD jack in a cabinet or
chassis.
----End

5.4 Environmental Requirements

5.4.1 Space and Airflow Requirements

To allow for servicing and adequate airflow, observe the following space and
airflow requirements:
Issue 09 (2021-01-12)
Both ends of an ESD wrist strap must be in good contact. One end contacts
your bare skin, and the other is securely inserted into the ESD jack in the
chassis. For details, see
During parts replacement, keep new server components in ESD bags before
installation, and place removed server components on conductive mats for
temporary storage.
Do not touch welding points, pins, or exposed circuits.
NO TE
● For details about the safety precautions to be observed when you install or replace
servers and their parts, see the
● Suitable for mounting on concrete or other non-combustible surface only.
Install the server in an access-restricted area.
Keep the area in which the server is located clean and tidy.
To facilitate heat dissipation and maintenance, keep a clearance of 800 mm
(31.50 in.) between walls and the front and rear doors of the cabinet.
Do not block the air intake vents. Otherwise, air intaking and heat dissipation
will be affected.
Copyright © Huawei Technologies Co., Ltd.
5.3.2 ESD Wrist
Strap.
Figure
5-2.
Huawei Server Safety Information
5 Installation and Configuration
.
45