Label

5.3 ESD Protection

5.3.1 Operation Instructions

To minimize ESD damage, observe the following precautions:
Issue 09 (2021-01-12)
Lay ESD floors or ESD cushions in the entire equipment room, and use ESD
chairs. The equipment room is equipped with ESD clapboards, ESD screens,
and ESD curtains.
All floor-standing electric devices, metal frames, and metal chassis shells in
the equipment room must be directly grounded. All electric meters or tools on
a workbench must be connected to the common ground point of the
workbench.
Monitor the temperature and humidity in the equipment room. The heating
system reduces indoor humidity and increases ESD.
Place components in ESD bags or boxes during transportation or storage.
Wear an ESD wrist strap when installing or removing a server component.
Ensure that the ground terminal of the ESD wrist strap is inserted into the
ESD jack in the chassis.
Before touching a device, ensure that you are wearing ESD clothing and ESD
gloves (or wrist strap), and remove any conductive objects (such as watches
and jewelry).
Figure 5-1
before you touch a device.
Figure 5-1 Conductive objects to be removed
Copyright © Huawei Technologies Co., Ltd.
Meaning
Description
No stacking
Do not stack after unpacking. This
may cause device damage.
No handling
Do not carry the device using its
handle. This may cause injury or
damage.
Multiple inputs
This label indicates that the device
has multiple power inputs.
Disconnect all power inputs before
you power off the device.
shows conductive objects that must be removed