Huawei TaiShan 200 23280 User Manual page 167

Table of Contents

Advertisement

TaiShan 200 Server (Model 2280)
User Guide
Issue 09 (2021-01-12)
Paramet
Descripti
er
on
<option>
Serial
port
direction
To set the serial port by using a jumper, do as follows:
a.
Power off the server and remove the power cables.
b.
Place a jumper cap on a COM_SW pin. For details about the jumper
position, see
Figure
You can place a jumper cap on any of them.
Copyright © Huawei Technologies Co., Ltd.
9 Common Operations (iBMC V3.01.00.00 or Later)
Value
The value options of this parameter and the value
meanings vary according to the server model. You
are advised to run the ipmcget -d serialdir
command to view the value options.
For the server, the options are as follows:
– 0: sets the serial port on the server panel as the
system serial port.
– 1: sets the serial port on the server panel as the
iBMC serial port.
– 2: sets the SOL port as the system serial port.
– 3: sets the SOL port as the iBMC serial port.
– 4: sets the serial port on the SDI V3 card panel as
an SCCL port.
– 5: sets the serial port on the SDI V3 card panel as
an IMU port.
– 6: sets the serial port on the SDI V3 card panel as
an SCCL port.
– 7: sets the serial port on the SDI V3 card panel as
an IMU port.
To set the panel serial port as the iBMC serial port,
run the ipmcset -d serialdir -v 1 command.
NOTE
– If no SDI V3 is installed in a server, <option> can be 0
to 3 only.
– If one SDI V3 card is installed, the values 4 and 5 are
available for setting the ports on the SDI V3 in I/O
module 1 or 2.
– If two SDI V3 cards are installed, the values 4 to 7 are
available. The values 4 and 5 are used for setting the
ports on the SDI V3 in I/O module 1, while the values 6
and 7 are for the ports on the SDI V3 in I/O module 2.
9-16. The pins 1, 3, 5, and 7 are all COM_SW pins.
159

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents