TaiShan 200 Server (Model 2280)
User Guide
----End
Issue 09 (2021-01-12)
Active Secure Firmware Version: 5.0.80.0 (21:21:55 Feb 29 2020)
Backup Secure Firmware Version: 5.0.80.0 (21:21:55 Feb 29 2020)
----------------- Product INFO -----------------
Product
ID:
Product
Name:
BIOS
Version:
-------------- Mother Board INFO ---------------
Mainboard
BoardID:
Mainboard
PCB:
------------------- NIC INFO -------------------
NIC 1 (TM280) BoardID:
NIC 1 (TM280)
PCB:
--------------- Riser Card INFO ----------------
Riser1
BoardName:
Riser1
BoardID:
Riser1
PCB:
Riser2
BoardName:
Riser2
BoardID:
Riser2
PCB:
-------------- HDD Backplane INFO --------------
Disk BP0
BoardName:
Disk BP0
BoardID:
Disk BP0
PCB:
Disk BP0
CPLD Version:
---------------- IO Board INFO ----------------
IOBoard0 ProductName:
IOBoard0
BoardID:
IOBoard0
PCB:
-------------------- PSU INFO -------------------
PS1
Version:
PS2
Version:
------------- Security Module INFO -------------
Specification
Type:
Specification Version:
Manufacturer
Name:
Manufacturer Version:
▪
CPLD Version: complex programmable logical device (CPLD) version
of the server
▪
BIOS Version: BIOS version of the server
▪
Active iBMC Version: active iBMC version of the server
▪
Backup iBMC Version: backup iBMC version of the server
e.
Query the health status of the server.
iBMC:/->ipmcget -d health
System in health state
▪
If "System in health state" is displayed, no further action is required.
▪
If alarm information is displayed, go to the next step.
f.
Check for generated alarms.
iBMC / # ipmcget -d healthevents
Event Num | Event Time
1
| 2019-02-10 00:52:23 | Minor
2
| 2019-02-10 01:37:42 | Minor
temperature.
3
| 2019-02-10 00:52:23 | Minor
4
| 2019-02-10 00:52:19 | Major
backplane is incorrectly connected.
g.
Clear alarms. For details, see
Handling
.
Copyright © Huawei Technologies Co., Ltd.
0x0007
XXXX
(U75)1.13
0x0005
.A
0x0067
.A
BC82PRUN
0x0093
.A
BC82PRUN
0x0093
.A
BC82THBB
0x004a
.A
(U31)0.05
BC82IOEA
0x0063
.A
DC:113 PFC:113
DC:111 PFC:111
TPM/TCM
N/A
N/A
N/A
| Alarm Level | Event Code | Event Description
| 0x12000021 | get description failed.
| 0x12000013 | Failed to obtain data of the air inlet
| 0x12000019 | Right mounting ear is not present.
| 0x28000001 | The SAS or PCIe cable to front disk
TaiShan Rack Server iBMC Alarm
5 Installation and Configuration
102