Leak Detection (power cut off) - All Variants
Enhanced Leak Detection (Flood prevention) Available as Optional Extra.
NOTE: If this machine is equipped with a leak detection device. When leaking is
detected the dispense operation will be cut off automatically.
To reset:
1
Unplug the machine.
4
If enhanced Leak Detector is
fitted as optional extra: locate
the Leak Detector valve.
If leak detector is fitted as optional extra, reset the red lever (push it in)
Borg & Overström
Locate the source of leakage
and rectify.
B4.2 Install & Operation Manual
2
5
Reset the red lever (push it in).
14
3
Locate the detection probe which
can be found in the bottom rear
left hand corner. Dry the probes
and internal area with a dry cloth.
H O T
6
Reconnect the power to machine
and test operation.