Fault Diagnosis: Water Leaks
Problem/Report
Water lying on top edge of
lower door panel and/or bottom
of Cabinet.
Water lying in bottom of machine.
Fault Diagnosis: Miscellaneous
Problem/Report
Repeating beeping noise
No LED Control Lights
Machine Shakes on Start-up
Tripping out Electricity Supply
Borg & Overström
Possible Cause
Overflowing Drip Tray waste
container.
Level Sensors not working.
Leak in supply inlet pipe work and/
or filter.
Leak from machine water pipe
work fittings.
Possible Cause
Level Sensor fitted and tank full.
No electricity to Machine.
Check Fuse in IEC Socket.
Control PCB not working (Machine
working normally otherwise).
Compressor Starting.
Level Surface.
Uneven Surface.
Missing Fixings.
Machine in high humidity
environment.
Electrical circuitry faults.
B4.2 Install & Operation Manual
Suggested Action
Empty Waste Container and check
drainpipe is not blocked.
Check operation/repair/replace
as required.
Locate and repair accordingly.
Locate and repair accordingly.
Check pressure and fit pressure
reducing valve if needed.
Suggested Action
Empty Level Sensor tank.
Check power supply and reconnect
as necessary (Also check out other
symptoms as described separately).
Replace if necessary.
Check/replace PCB.
No action needed. This is quite
normal.
Level up machine using adjustable
feet.
Replace missing fixings.
Discuss possible repositioning with
customer.
Test, identify and address
accordingly. See Electrical
Diagrams.
Please contact technical support