Borg & Overström
Leak Detection
NOTE: This machine is equipped with a leakage detection device. When leaking is
detected, the dispense operation will be cut off automatically. This is indicated by a
blue LED flashing at the base of the tap.
To reset:
1
Unplug the machine and remove
the protective cover.
4
Locate the Leak Detector
valve.
Install & Operation Manual
2
Locate the source of leakage
and rectify.
5
Reset the red lever (push it in).
12
3
Locate the detection probe which
can be found in the bottom at
the rear of the machine. Dry the
H O T
probes and internal area with a
dry cloth.
6
Reconnect the power to machine
and test operation.