Sanitisation Guide

Borg & Overström's recommended sanitisation schedule is a minimum of 6 months
for a filter change and internal water pathway sanitisation using Sterizen
(Order code: 461007), and a minimum weekly for external cleaning, using
Sterizen
Sanitising Solution (Order code: 500023).
®
NOTE: Failure to use sanitising products and processes approved by Borg & Overström
will invalidate your warranty. Before beginning the sanitation process please ensure that
water is turned off at the mains and refer to the sanitisation liquid MSDS documentation
for further information. Use bioguard hand gel and ensure gloves are worn.
1
Briefly press cold/ambient
dispense buttons to release
internal water pressure from
the machine.
5
Turn on incoming water, allow
service cartridge/doser to fill.
Borg & Overström
2
Remove the existing cartridge.
6
PINK
Dispense water using the
cold button until the water
appears pink. Repeat with
sparkling button if present.
Briefly press the ambient
button too.
B4.2 Install & Operation Manual
3
Add 25 ml of Bioguard
Internal Sanitisation fluid to a
clean and empty service filter
cartridge.
7
Leave the solution inside
machine for sanitisation
(minimum 5 minutes) while
thoroughly cleaning the
machine externally, pay
particular attention to the
dispense faucet and buttons.
12
75 fluid
®
4
Connect the service cartridge
to machine.
8
borg&overström
If a Waste Overflow System
is fitted, empty this and flush
through with a small amount
of sanitisation fluid if needed.
Remember to include the drip
tray and connecting pipe work.
AU