10.3 Adjusting the thread tension plate
Fig. 36: Adjusting the thread tension plate
(1) - Tension disks
(2) - Washer
To adjust the thread tension plate:
1. Pull the needle thread out of the thread tension.
2. Press Extras > Service > Multitest (Multi test).
3. Input the password (25483).
4. Press Fadenspannung (Thread tension) > Kalibrierung
5. Loosen screw (4) and nut (3).
6. Loosen the washer (2).
7. Turn the washer (2) clockwise as far as it will go.
The tension disks lie flush on each other.
8. Use a (lead) pencil to mark 12 o'clock on the disk (2) and turn it
9. Press ESC or OK.
10. Press Kalibrierung 1 (Calibration 1).
11. Turn back the nut (3) until reaching the screw head of the screw (4).
12. Screw in the screw (4) until the nut (3) is positioned approx. 2 mm
13. Loosen the screw (4) until the tension disks (1) tighten.
14. Using an open-jaw wrench, lightly tighten the nut (3) and slowly loosen
15. Press ESC.
16. Press Kalibrierung 3 (Calibration 3).
17. Hold the screw (4) still with a screwdriver, and tighten the nut (3).
50
(Calibration 3).
approx. 15-30° clockwise.
in front of the washer (2).
the screw (4) until the tension disks (1) tighten.
Take care that the washer (2) does not twist.
Adjusting the needle thread tension
(3) - Nut
(4) - Screw
Service Instructions 911-210-10 - 00.0 - 06/2020
①
②
③
④