User manual
C. How to set up Simulcrypt in the TDX
1. Prerequisites
•
TDX should be connected to the CAS System – see installation drawing on page I.
•
TDX should have quality input signal to use
•
User must have valid license(s)
The TDX configuration port has to be in the same VVLAN as the CAS server,
➢
if the CAS server has IP 10.10.85.1
– then the TDX has to be set up to 10.10.85.xx
•
Enter relevant information in "CAS system settings" from TDX Admin
options window.
•
Enter mandatory fields in the Service tool, as shown in example.
•
Click OK and apply
CAS system ID
•
As shown in the CAS server Simulcrypt settings w/o
zeroes/end. Ie. 0x4AFC000 is 0x4AFC
•
Panaccess: 0x4AFC / Samsung: 0x112
EMM server port
•
As defined in the CAS server. Default: 5000
2. How to setup a service to be scrambled
•
Route non scrambled service to
scrambler
•
Configure "input" in TDX as example
below
•
Click Update and Apply – remember
when clicking Update,
previously selected services will be
removed
Click on CA then on Simulcrypt scramblers. Click on Setup
ECM server IP adress
•
IP adress from the CAS server
ECM server IP port
•
As defined in the CAS server.
•
Panaccess: 12500 / Samsung: 9999
31
EN