Triax 492055 User Manual

Qam output module
Hide thumbs Also See for 492055:

Advertisement

Quick Links

User guide
QAM output module
Model
QAM output module
Version
891076E
Item no.
492055
492056
12 - 2013
EN
triax.com

Advertisement

Table of Contents
loading

Summary of Contents for Triax 492055

  • Page 1 User guide QAM output module Model Item no. QAM output module 492055 492056 triax.com Version 891076E 12 - 2013...
  • Page 2: Table Of Contents

    Contents Contents Disposal ..........................3 Box content ..........................3 QAM module .......................... 3 Labels ............................. 4 Installation of module ......................4 Removal of module ....................... 4 CAM/Smart card ........................5 Status LED ..........................5 Log in ............................7 CA Modules window ......................8 CA Modules configuration window ..................
  • Page 3: Disposal

    Introduction Disposal Within in the European Union this label indicates that the product cannot be disposed of with the general household waste. Neither the headend nor the input and output modules can be disposed of with the general household waste. For proper treatment and recycling of old products, please take them to designated collection points in accordance with your na- tional legislation.
  • Page 4: Labels

    Basics Labels A label is placed on the output module where you can write the information regarding the configuration of the module. Besides the information that you write on the label, the module type and part number are also displayed on the label. Note The coloured part of the label informs you of the module type.
  • Page 5: Cam/Smart Card

    Basics CAM/Smart You can insert 2 Conditional Access modules (CA) into each of those output card modules that have Common Interface (CI) slots. Each CA module is able to unscramble at least one service. Which services depend on the service provider of the CA module and smart card. Status LED There is a status LED on the front of each module.
  • Page 6 Basics Green - flashing The output module receives data. Green - constant on The output module receives valid services. When starting the TDX system the output module and the system controller negotiate connection speed. If the LED continues to be red either the output module or the system controller has not been inserted cor- rectly.
  • Page 7: Log In

    TDX Service Tool Log in When you have loaded the TDX Service Tool from the TDX headend system to your laptop/computer the Login window of TDX Service Tool is displayed. When you have pressed the Log in button the System window is displayed. Rev.
  • Page 8: Ca Modules Window

    TDX Service Tool CA Modules Click the CA Modules tab in the TDX Service Tool to display the CA Modules window window. The first time you display the CA Modules window in a new configuration the module list only displays the number and type of the CA modules that you have inserted in the main and subunits.
  • Page 9: Ca Modules Configuration Window

    TDX Service Tool CA Modules con- When you open the Configuration window for a CA module in a new configu- figuration window ration, only default values are displayed. Card speed Open the drop-down list with the card speeds if you want a higher card speed than the default card speed.
  • Page 10 TDX Service Tool The Descramble button is default. Click the Scramble (PanAccess) button if you want to scramble services using the PanAccess Scrambler. Service list area Select the service(s) that you want to descramble in the Service list area by clicking the service(e). Scrambled services are marked with a dollar sign - $.
  • Page 11 TDX Service Tool The ER checkbox should not be enabled for services where signals are not transmitted on a 24-hour basis. Filter option To change the Filter options for a service, click the Setup button of the service in question to open the Filter options window.
  • Page 12 TDX Service Tool To descramble only selected audio PIDs you have to de- select the Descramble all audio PIDs checkbox. Deselecting the Descramble all audio PIDs checkbox, dis- plays a field with a drop-down list below the checkbox. Open the drop-down list and select the the language of the audio PID you want to descramble.
  • Page 13 TDX Service Tool If the language of the audio PID you want to descram- ble is not displayed in the list you can enter a three letter string signifying the language you need. Click OK to return to the Configuration window. Common Clicking the Common interface button gives you access to information from the smart card inserted in the CA...
  • Page 14 TDX Service Tool Submit When you have made all the required selections, click the Submit button to save this information in the headend system and return to the CA Modules window. The selected service(s) is now listed in the CA Modules window next to the CA module.
  • Page 15: Delete Ca Module

    TDX Service Tool Delete CA module If you want to remove a CA module, click the Delete button of the module in question in the CA Modules window. A message window is displayed asking you to confirm that you want to re- move the output module.
  • Page 16: Output Window

    TDX Service Tool Output window Click the Output tab in the TDX Service Tool to display the Output window. The first time you display the Output window in a new configuration the module list only displays the number and type of output modules that you have inserted in the main and subunits.
  • Page 17: Configuration Of Output Modules

    TDX Service Tool Configuration of output modules The first time the Service Tool displays the Configuration window for an out- put module in a new configuration the fields in the window will display default values and/or be empty, and the output module is disabled. Disabled output If you want to enable this module, click the Disabled output checkbox.
  • Page 18 TDX Service Tool You can configure a QAM module either: • by using the specifications of the channel plan • by entering a frequency manually. Channel, Frequen- Using the channel plan definitions: cy and Channel Open the drop-down list with the predefined channels spacing and select the channel you want to use.
  • Page 19 TDX Service Tool In the Select Services window you can select the ser- vice or services that you want to output. Note By clicking one of the underlined column headlines you can sort the list into alphabeti- cal or numerical order. Click the checkbox to the right of the service(s) you want.
  • Page 20 TDX Service Tool The SID must to be unique inside a network with the same Original Network ID (ONID) and Transport Stream ID (TS-ID). All QAM output modules in your TDX head- end system uses the same ONID but separate TS-IDs for each output.
  • Page 21 TDX Service Tool Note The services you have selected will no longer be available in the TDX-pool for other output modules. Click OK to return to the Configuration window. Services from input module To select the services from a particular input module, open the drop-down list of the Select input field and select “Transparent”...
  • Page 22: Payload Monitor

    TDX Service Tool Manual SDT By default this checkbox is deselected. version If it is necessary to control when a new SDT version is sent, then select the checkbox and enter a version number (0-31) in the field next to the checkbox. It is recommended that you keep the default value.
  • Page 23: Status Information

    TDX Service Tool Status informa- Status information about the output is placed at the bottom of the Configura- tion window. tion Watch the status information to check that the output module. Status Informs you whether output is enabled or disabled. SW revision Displays the software version of the output module.
  • Page 24: Delete Output Modules

    TDX Service Tool When you return to the Output window the configuration of the output mod- ule is displayed in the module list. Now you can configure the other outputs of the first QAM module and then continue to configure the other output modules, following the procedure just described.
  • Page 25: Event Log

    TDX Service Tool Event log If you want to display a history of the events related to the QAM output, click the Log button of the output in question to open the Event Log window. Rev. 01 - 2014 - E 891076E_492055_492056_TDX_QAM_module - User Guide - EN.indd 25 17-01-2014 11:25:52...
  • Page 26: Network Window

    TDX Service Tool Network Click the Network tab in the Service Tool to display the Network window. window The first time you display the Network window the fields in the window will display default values and/or be empty. The service list area will display all the digital services you have configured to output using the Output tab.
  • Page 27 TDX Service Tool Basically, the drop-down list gives you at choice be- tween using a barker channel or using all outputs for transmitting EIT informationl. By using a barker channel all EIT information, i.e. actual present/following and actual schedule EIT for all ser- vices, will be transferred from the individual outputs to the barker channel thereby making more room/ payload available to the transmission of services.
  • Page 28 TDX Service Tool If you prefer not to use a barker channel you have the following options: Full Actual - Full Other All outputs will have all EIT information available, so all actual present/following, actual schedule, other present/following and other schedule EIT are sent out with all muxes.
  • Page 29: Channel List

    TDX Service Tool When you have entered the values you require you have to click the Submit button to enter this information into the headend system. Remember to click the Apply button in the upper right-hand corner to save new settings. Channel list When you have finished configuring all the output modules you have inserted in the headend units the Channel list tab displays a list with all the channels...
  • Page 30: Save Configuration

    TDX Service Tool Save configu- An important button when you change your configuration of the headend system is the Apply button placed in the upper right-hand corner of the TDX ration Service Tool window. Apply Whenever you have made changes in your configuration, “Apply”...
  • Page 31: Your Notes

    Your notes Rev. 01 - 2014 - E 891076E_492055_492056_TDX_QAM_module - User Guide - EN.indd 31 17-01-2014 11:25:53...
  • Page 32: Manufacturer

    TRIAX confirms that the product conforms to relevant EEC harmonised standards and conse- quently can carry the CE-mark. Relevant harmonised standards: DE/EN 60728-2 2010, DS/EN 60728-11 2010 and DS/EN 50083-2 2006 This document is only valid with the signature of the person responsible for CE-marking by Triax Date: October 2012 Signature: triax.com/support Copyright ©...

This manual is also suitable for:

492056

Table of Contents