Specification; Specifications - SMC Networks ISE35 Operation Manual

Digital pressure switch
Hide thumbs Also See for ISE35:
Table of Contents

Advertisement

Specification

■Specifications

Model No.
Rated pressure range
Set pressure range
Proof pressure
Setting and display resolution
Applicable fluids
Power supply voltage
Current consumption
Switch output
Max. load current
Max. applied voltage
Residual voltage
Response time
Chattering-proof function
Short circuit protection
Repeatability
Hysteresis mode
Hysteresis
Window comparator mode
Display method
Indication accuracy
Indicator light
Enclosure
Environment
Ambient temperature
Lead wire with connector
(for option "L")
Standard
ISE35
0 to 1 MPa
-0.1 to 1 MPa
1.5 MPa
0.01 MPa
Air, inert gases, and incombustible gases
12 to 24 VDC ±10% with voltage ripple or less
55 mA or less (With no load)
NPN or PNP open collector output
80 mA
30 V (During NPN output)
1 V or less (80 mA load current)
1 s (0.25, 0.5 ,2 ,3 selectable)
Provided
±1%F.S.
Variable (from 0)
3-digits 7-segment display, dual-color display (Red/Green),
A switch can be operated simultaneously.
±2%F.S. ±1 digit (25±3 °C reference)
OUT: LIT When ON (Green)
IP40
-5 to 50 °C (No freezing)
Oil resistance vinyl cabtyre cable
3.4, 2 m
3 cores
Sectional area of conductor: 0.2 mm
Outside diameter of insulator: 1.12 mm
CE marked (EMC directive/RoHS directive), UL/CSA
-33-
2
(AWG25)
No.PS※※-OMJ0004-E