Specification

■Specifications
Rated pressure range
Set pressure range
Proof pressure
Min. display unit
Applicable fluid
Power supply voltage
Current consumption
Switch
Output
Maximum load current
Max. applied voltage
Residual voltage
Response time
Short circuit protection
Repeatability
Hyster
Hysteresis mode
esis
Display
Indicator accuracy
Indication LED
Enclosure
Ambient temperature range
Environ
ment
Withstand voltage
Insulation resistance
Temperature characteristic
Lead wire
Standard
1: If the applied pressure fluctuates around the set value, the hysteresis must be set to a value more than the amount of fluctuation or
chattering will occur
Air, inert gas and non-flammable gas
24 VDC ±10%, ripple max. 10%
NPN or PNP open collector
OUT1: General-purpose、OUT2: Valve control
Max. 2 V (at 80 mA load current)
2.5 ms or less (response times available for anti-chattering function: : 20,
100, 500, 1000 or 2000 ms)
Adjustable (can be set from 0)
3 1/2 digits, 7-segment display, color display (Red)
+/-2%F.S., +/-1 digit (at ambient temperature 25+/-3
Light when ON OUT1: Green OUT2: Red
1000 VAC for 1 minute between live parts and case insulation resistance
50 M or more at 500 VDC Between lead block and case
ce
 3.5, 2 m
cable
5 cores
Sectional area of conductor: 0.15 mm
Outside diameter of insulator: 1.0 mm
CE
-54-
100.0 to -100.0 kPa
105.0 to -105.0 kPa
500 kPa
0.1 kPa
(with polarity protection )
pk-pk
40 mA or less
80 mA
DC26.4 V
Provided
±0.2%F.S.±1 digit
1
IP40
o
5 to 50
C
o
±2%F.S. (25
C referen)
2
(AWG26)
/UKCA
marking, RoHS
o
C)
NO.ZL3-OM00701-A