Operation

1. Pull off the adhesive tape from the back of the wireless sensor module.
2. Align the sensor module so that the notch points inwards towards the
window and attach it onto the frame. To also detect the tilting movement
of the window, the sensor should be mounted in the upper quarter of
the frame.
3. Pulls off the adhesive tape from the back of the magnet.
4. Align the notch of the magnet with the notch of the sensor and attach
the magnet onto the frame. The sensor and magnet should be located
close together (max. 5 mm), a direct contact is not necessary.
9.
Operation
9.1

Temperatures

9.1.1

Limitation

With the limitation you define a temperature range within which you can se-
lect the temperatures as you wish. A temperature outside this range cannot
be selected.
9.1.2

Comfort temperature

Set your personal comfort temperature.
9.1.3

Setback temperature

Set your personal setback temperature.
9.1.4

Offset temperature

With the offset temperature you can correct the temperature measurement
in the wireless thermostat by ± 3 degress Celsius. This may be necessary if
environmental influences such as a cold outside wall distort the control.
9.1.5

Temperature unit

You can choose between the temperature units Celsius and Fahrenheit.
9.2

Time profiles

If you press the Auto/Manu button (see Illust. 1 on page 9), you
can switch between the individual time profiles.