R-Tronic with mote 320
Illust. 4: Wall attachment of the fixing plate
3. Insert the R-Tronic wireless thermostat into the fixing plat from above.
f The R-Tronic wireless thermostat is now ready for the teach in process
(see section 8.2.1 on page 22).
7.3
Wall attachment of the fixing plate and flush-mounted power
pack
DANGER
Danger of electric shock when connecting the flush-mounted
power pack to the power supply of the house
Danger to life due to contact with live components.
f Switch off the relevant electrical circuit before carrying out any
work.
f Check that no voltage is present.
f The connection must only be carried out by a qualified electrician.
CAUTION
Risk of fire due to overcharging of the batteries
If batteries are inserted into the R-Tronic and it is additionally con-
nected to the flush-mounted power pack, there is a risk of overcharg-
ing of the batteries.
f Never insert batteries into the R-Tronic if it is connected to the
flush-mounted power pack.
Mount the flush-mounted power pack so that the primary and the
secondary lines cannot touch each other. If necessary, you can fix
these lines, e.g. with a cable tie, to ensure local separation.
1. Establish the electrical connection between the flush-mounted power