Set Platform Event Forwarding Address; Table B-21 Netfn 0X32, Cmd 0X80 - ABACO VMICPCI-7055 Hardware Reference Manual

Powerpc based compactpci
Table of Contents

Advertisement

B.5.3 Set Platform Event Forwarding Address
This command sets the slave address and the LUN of the Event Receiver to which the Platform Events
are forwarded.

Table B-21 NetFn 0x32, Cmd 0x80

If the forwarding address is 0 (by default, or deliberately set), events will not be forwarded.
In all cases, any Platform Events will be acknowledged back to the original sender. The VMICPCI-7055/
CPCI-7055RC should not acknowledge the forwarded event back to the IPMI controller.
68 VMICPCI-7055/CPCI-7055RC Hardware Reference Manual
Byte
Request-data
1
2
Response-data
1
Value
Data Field
XXh
2
[7:1] – I
C slave
address
[0] – always 0
XXh
[7:2] – 0
[1:0] – LUN
XXh
Completion code
Comments
Publication No. 500-657055-000 Rev. G