B.1.14 Read FRU Data
This command returns the specified data from the FRU Inventory Info area. No parsing of the FRU data
is performed by the IPMI subsystem; system management software is responsible for interpreting the
FRU data.

Table B-13 NetFn 0x0A, Cmd 0x11

The FRU data conforms to the IPMI FRU Information Storage Definition v 1.0 specification. All Abaco
IPMI-enabled boards come with the FRU data preloaded; the specific data is documented in "FRU Data
Specification" on page 64.
B.1.15 Write FRU Data
This command writes the specified byte or word to the FRU Inventory Info area. No parsing of the FRU
data is performed by the IPMI subsystem; system management software is responsible for creating valid
FRU data structures and writing the data to the FRU area.

Table B-14 NetFn 0x0A, Cmd 0x12

Publication No. 500-657055-000 Rev. G
Byte
Value
Request-
1
XXh
data
2
XXh
3
XXh
4
XXh
Response-
1
00
data
2
XXh
3:2+
N
Byte
Request-
1
data
2
3
4:3+N
Response-
1
data
2
Data Field
FRU device ID. FFh
reserved.
FRU Inventory offset
to read. LS Byte.
FRU Inventory offset
to read. MS Byte.
Count to read – 1
based
Completion code
Count returned – 1
based
Requested data
Value
Data Field
XXh
FRU device ID. FFh
reserved.
XXh
FRU Inventory offset to
write. LS Byte.
XXh
FRU Inventory offset to
write. MS Byte.
Data to write
XXh
Completion code
00h – successful
80h – Write protected
XXh
Count written – 1 based
Comments
Offset is in words or
bytes per device
access type returned
in the FRU Inventory
Area Info command.