Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
ABACO Manuals
Single board computers
VMICPCI-7055
Hardware reference manual
Platform Events; Table B-18 Netfn 0X04, Cmd 0X02 - ABACO VMICPCI-7055 Hardware Reference Manual
Powerpc based compactpci
Hide thumbs
ABACO
VMICPCI-7055
Hardware Reference Manual
1
2
3
4
5
6
7
8
Table Of Contents
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
page
of
71
Go
/
71
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
B.3 Platform Events
The Abaco IPMI subsystem contains several sensors for reading the voltages and temperature of the
system. Each sensor is configured with a threshold, hysteresis, and nominal value. When the value of a
sensor crosses a threshold, a platform event is sent to the "Event Receiver".
The following events are generated by the Abaco IPMI Subsystem:
• Threshold Events – Events of this type are generated if the sensors exceed their threshold settings.
Threshold events are either an Assertion Event or a De-Assertion Event.
Table B-18 NetFn 0x04, Cmd 0x02
The Generator ID field is a required element of an Event Request Message. For IPMB messages, this field
is equated to the Requestor's Slave Address and LUN fields. Thus, the Generator ID information is not
carried in the data field of an IPMB request message.
Publication No. 500-657055-000 Rev. G
Byte
Request-
-
data
1
2
3
4
5
6
7
Response-
1
data
Value
Data Field
-
Generator ID (RqSA,
RqLun)
03h
EvMRev
XXh
Sensor Type
XXh
Sensor #
XXh
[7] - Event Dir
0b = Assertion Event
1b = De-assertion
Event
[6:0] - Event Type
XXh
Event Data 1
[7:6] – 01b = trigger
reading
[5:4] – 01b = trigger
threshold
[3:0] - offset from Event/
Reading
code for threshold
event
XXh
Event Data 2
XXh
Event Data 3
XXh
Completion Code
Comments
IPMB v 1.0 message
02h = voltage sensors
01h = temperature
sensors
Sensor numbers will
be one of 41h, 42h,
43h, 44h, 60h or 61h
Event Type indicates
the type of threshold
crossing that
produced the event.
in byte2
value in byte3
Sensor reading
Threshold value that
triggered event.
IPMI Firmware and OEM Extensions 65
Table of
Contents
Previous
Page
Next
Page
1
...
63
64
65
66
67
68
69
70
Advertisement
Table of Contents
Related Products for ABACO VMICPCI-7055
ABACO VMIVME-1184 Series
This manual is also suitable for:
Cpci-7055rc
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL