Appendix A - Modbus Variable Map - Graco Informer G3000 Instructions Manual

Fluid monitoring kits
Hide thumbs Also See for Informer G3000:
Table of Contents

Advertisement

Appendix A A A - - - Modbus
Modbus Variable
Appendix
Appendix
Modbus
Table
Table 1 1 1 Device
Table
Device Identification
Device
Identification Registers
Identification
Register
Register
Register
Informer
Informer
Informer
Permissions
Permissions
Permissions
Modbus
Modbus
Modbus
Register
Register
Register
Read Only
401040
Read Only
401042
401044
Read Only
Read Only
401072
Read Only
401074
Read Only
401076
Read Only
401078
Read Only
401080
Read Only
401082
Read Only
401084
401086
Read Only
Table 2 2 2 Run
Run Registers
Registers
Table
Table
Run
Registers
Register
Informer
Register
Register
Informer
Informer
Permis-
Permis-
Permis-
Modbus
Modbus
Modbus
sions
sions
sions
Register
Register
Register
Read/Write 402000
Read/Write 402001
Read/Write 402002
Read/Write 402003
Read/Write 402004
Read/Write 402005
Read/Write 402006
Read Only 402008
Read/Write 402010
Read/Write 402012
Read Only 402014
Read/Write 402016
Read/Write 402017
Read/Write 402019
3A2040H
Variable Map
Variable
Registers
Registers
Description
Description
Description
Software Version Major
Software Version Minor
Software Version Build
Serial Number String - Bytes 0-3
Serial Number String - Bytes 4-7
Serial Number String - Bytes 8-11
Serial Number String - Bytes 12-15
Serial Number String - Bytes 16-19
Serial Number String - Bytes 20-23
Serial Number String - Bytes 24-27
Serial Number String - Bytes 28-31
Description
Description
Description
Date, Year
Date, Month
Date, Day
Time, Hour
Time, Minute
Time, Second
Alarms Needing
Acknowledgment
Current Grand Total
Current Batch Total
Current Maintenance
Total
Current Flow Rate
Calibration Mode
Calibration, Measured
Volume
Calibration, Actual
Dispensed Volume

Appendix A - Modbus Variable Map

Map
Map
Size
Units
Size
Size
Units
Units
16 Bit
YY
16 Bit
MM
16 Bit
DD
16 Bit
HH
16 Bit
MM
16 Bit
SS
32 Bit
Bit-field
alarms
32 Bit
cc
cc
32 Bit
cc
32 Bit
32 Bit
cc/min
16 Bit
0-off, 1=on
32 Bit
pulses
cc
32 Bit
Size
Size
Size
Units
Units
Units
32 Bit
32 Bit
32 Bit
32 Bit
String, 4 Bytes
32 Bit
String, 4 Bytes
32 Bit
String, 4 Bytes
32 Bit
String, 4 Bytes
32 Bit
String, 4 Bytes
32 Bit
String, 4 Bytes
32 Bit
String, 4 Bytes
32 Bit
String, 4 Bytes
Low
High
Notes
Low
Low
High
High
Notes
Notes
Limit
Limit
Limit
Limit
Limit
Limit
1
99
1
12
1
31
0
23
0
60
0
60
0
0
0b0001–high
flow alarm;
0b0010 — low
flow alarm;
0b0100–main-
tenance target
— set bit to 0 to
reset
0
32-bit
0
999999 Write 0 to reset
0
999999 Write 0 to reset
0
65536
0
1
0
32-bit
0
32-bit
35

Advertisement

Table of Contents
loading

Table of Contents