Installing Cables And Power - Omron AnyFeeder Series Integration Manual

Table of Contents

Advertisement

NOTE: The Aux I/O connector is not used in an Omron Adept system.
Description
Function
J1
High Power on
servo motor
J2
RS232
J4
Aux I/O

Installing Cables and Power

The AnyFeeder requires the following cable connections:
the servo motor cable (supplied)
l
the RS-232 serial communications cable (supplied)
l
The AnyFeeder is equipped with fuses to protect the internal components.
The motor power 24 VDC input is protected with a 10 Amp fuse, and the parallel I/O 24 VDC
lines are protected with a 3 Amp fuse. These fuses can be replaced in the field.
If you suspect a problem with one or both of these fuses, contact your local Omron Support.
Table 4-1. Electrical Connector Pinout
Type
D-sub-M
2 + 5
D-sub 9,
female
D-sub 15
AnyFeeder Integration Guide - Page 25
Chapter 4: System Installation
Pin
Pinout
#
A1
24 VDC
No. 1 (red)
A2
GROUND
No. 2 (blue)
2
RX
D-sub 9, female
3
TX
5
GROUND
1
Trigger out
Not used
4
GROUND
5
GROUND
6
24 VDC out
7
24 VDC out
8
Pick in
9
Flash in
14
Error Drive 1
15
Error Drive 2
Cable

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents