Melsecnet/h network module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Item
Batch
[Batch Setting]
Setting
button
Equal Assignment
Identical Point
Assignment
2 PARAMETER SETTINGS
56
2.2 Required Settings
Description
Clicking the [Batch Setting] buttons opens the "Batch Setting" window. The
number of points for LB/LW and LX/LY is set in a batch. (The "Batch Setting"
window for LB/LW and LX/LY are switched in conjunction with "Switch
Windows".)
Equally assign the range of the specified link device to the send range of the
target station.
LB/LX/LY points can be assigned in increments of 16, and LW points can be
assigned in increments of 1.
• Start Station: Enter the start station number of stations for which link
devices are equally assigned.
• End Station: Enter the end station number of stations for which link
devices are equally assigned.
• Start Device No.: Enter the start number of link devices to be equally
assigned.
• Number of Points: Enter the total points of link devices to be equally
assigned.
Assign the same specified points to LB/LW range to be sent by each station.
LB points can be assigned in increments of 16, and LW points can be
assigned in increments of 1.
Setting range
• Equal Assignment
• Identical Point Assignment
Default: Equal Assignment
Default: Blank
Default: Blank