6.13.7 Limits
The Limits feature will allow you to set the station's upper flow limits by either using the LEARN
mode or by setting them explicitly. The next 2 sections explain each of these methods.
NOTE:
6.13.7.1 Station Limits Using Learn Mode
This feature allows the controller to LEARN and set the station upper flow limits.
Controller operation:
• Each station is turned on one at a time. The amount of time it is on is determined by
the flow check delay time (1 to 6 minutes).
• The nominal flow reading is established by averaging the measured flow for the last
minute in which the station is on.
• The station upper limit is calculated taking the nominal value and adjusting upward by
the flow percentage (previously established).
• The new limit is saved in memory (non-volatile RAM).
You just press ENTER and the controller will automatically set the upper flow limits by
LEARNING them.
EXAMPLE: Set the controller to LEARN and automatically set all the station upper flow limits.
You think 30% is a good amount to add to the upper limits over and above what the
controller measures.
Continue to Press:
Press:
TUE
3
SETUP
Press:
Press:
SETUP
Chapter 6 Setup Key Operations
This SETUP function will be skipped if you have not enabled the flow
features.