Rain Master RME EAGLE User Manual page 84

For eg series controllers
Table of Contents

Advertisement

Rain Master Irrigation Systems
6.13.3 Unscheduled Flow Limit
This feature allows you to program the Unscheduled Upper Flow Limit. This is the maximum flow
that the controller will allow whenever there are no stations on. With no irrigation, and a Normally
Closed Master Valve, the typical installation should have no flow and the limit should be set to
zero. For systems which have a Normally Open Master Valve and the possibility of supplemental
watering due to quick coupler manual devices, you have the option of setting a non-zero value
which will be allowed when the controller does not have any active stations. If this value is
exceeded an unscheduled flow fault occurs.
NOTE:
EXAMPLE: Select an Unscheduled Flow Limit of 25 GPM.
Continue to Press:
Press:
MON
2
Display will indicate:
QUIT
Press:
The controller will return to the Automatic Mode.
6.13.4 Flow Check Delay
The Flow Check delay feature allows you to program a delay after any change of stations for which
no flow limits will be checked.
Whenever there is a change in stations (a station gets turned on or off) the controller will not check
for flow limit faults from the time of the change until this delay has expired; this gives the system
time to stabilize before any flow limit checking takes place.
The flow check delay can be set, from 1 to 6 minutes, in 1 minute increments.
Chapter 6 Setup Key Operations
This SETUP function will be skipped if you have not enabled the flow
features.
SETUP
ENTER
THU
5
UNSCH025
PROGRAM
Until display indicates:
RME EAGLE User Manual
UNSCH200
PROGRAM
Page 77

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents