9.0 TROUBLESHOOTING
9.1 MONITORING STATION FLOW
If the flow features have been enabled, using SETUP, there are three ways to observe the measured
flow in gallons per minute (GPM), of any station:
1. The measured flow is automatically displayed when the controller is executing one or more
programs.
2. When a manual system check is performed, the flow is shown for each station. Refer to
MANUAL SYSTEM CHECK for details.
3. When in SETUP mode, the measured flow can be observed on a per station basis when
utilizing the LIMITS sub-function. Refer to the LIMITS SETUP feature in the ADVANCED
SETUP PROGRAMMING section, of this manual, for more details.
9.2 FAULT DETECTION OVERVIEW
The RME EAGLE has the ability to detect and take corrective action for a number of field related
failure conditions. The operator is informed of any fault condition when the display alternates with
the following words:
FAULT
PROGRAM
PROGRAM
In addition to the display indication, the controller will sound an audible alarm once every six
seconds signifying a fault occurrence.
NOTE:
Pressing the REVIEW key reveals the specific fault type and momentarily suspends the audible
alarm.
WIRING
PROGRAM
FLOWMAIN
PROGRAM
Page 104
PRESS
REVIEW
PROGRAM
The audible alarm may be disabled using the SETUP function.
=
The problem is a field wiring short circuit on a station. The
station lights will illuminate to indicate which station(s)
have faults.
=
The problem is a Main Line Flow limit violation. Pressing
the REVIEW key again reveals the measured GPM at the
time the fault occurred.
Rain Master Irrigation Systems
Chapter 9 Troubleshooting