Hoist Motor Brake Adjustment (See Figure 5) - R&M LOADMATE LM Series Installation And Maintenance Manual

Table of Contents

Advertisement

LM01 I&M MANUAL/EN/11.30.2010

5.3.3 Hoist Motor Brake Adjustment (See Figure 5)

If maximum air gap of brake has been reached or will be exceeded before next inspection, readjust air gap.
Minimum air gap
X = 0.006" [ 0.15 mm ]
Before adjusting brake, remove load. Per ANSI Z244.1, lockout and tag main disconnect switch in de-
energized position. Follow other maintenance procedures outlined in this manual and ASME B30.16.
1. Remove brake cover and gasket.
2. With a feeler gauge, check three places near each mounting bolts, to measure air gap ( X ) between the
brake lining (Item 2 – Figure 5) and the coil (Item 1 – Figure 5).
3. To adjust the brake:
Tighten or loosen the screws (Item 5 – Figure 5). This compresses or decompresses the elastic
washers (Item 7 – Figure 5).
4. Check brake operation. Run load block up and down several times without a load to test operation of
brake. Then, lift a capacity load about one foot above floor, stop, and check that brake holds load.
5. Install gasket and brake cover.
This document and the information contained herein, is the exclusive property of R&M MATERIALS HANDLING, INC. and represents a non-public, confidential and proprietary trade secret
that may not be reproduced, disclosed to third parties, altered or otherwise emplo yed in any manner whatsoever without the express written consent of R&M MATERIALS HANDLING, INC.
Copyright © (2010) R&M MATERIALS HANDLING, INC. All rights reserved.
Maximum air gap
X = 0.020" [ 0.5 mm ]