Set COM2 or COM3 as Modbus RTU Slave:
7. Type
"isa5307 *x=PB"
port.
"P" means the COM Port number. (P = 2 or 3),
"B" means the baud rate. (B = 0 ~ 9)
1=2400,
7=115200,
Set COM2/3 baud rate and define it as a Modbus RTU
"PB" = 20 ~ 29, set
"PB" = 30 ~ 39, set
Ex: Set COM2 as Modbus RTU Slave Port, baud rate is 19200.
8. Exit the "7188xw" screen; else the COM1/COM2 is always in use.
9. Switch the "Init*" to "OFF" then power it up.
Recovery the COM2/COM3 Setting:
If you want to set COM2/COM3 as Non-Modbus RTU Slave Port, please type
*x=f"
to release it.
Getting Started: PAC-5007(P)/5107(P)/5207/5307 Ver. 1.0, 07/2010
to set the baud rate of COM2/3 and as a Modbus RTU Slave
2=4800,
3=9600,
8=300,
9=600,
COM2
to Modbus Slave Port
COM3
to Modbus Slave Port
4=19200,
5=38400,
0=1200
Please type the instruction according to
the controller model. (Ex.
ICP DAS
6=57600,
isa5307
*x=24)
"isa5307
.
3-13