76
Chapter 7—Punch In/Out Recording
Setting the Pre-roll Time
The pre-roll time can be set from 1 to 30 seconds, the default being 5 seconds.
Press the [UTILITY] button.
1
The UTILITY indicator lights up.
Use the JOG/DATA dial to select "PRE ROLL," and then press the [ENTER] but-
2
ton.
The currently set pre-roll time appears on the display.
Use the JOG/DATA dial to set the pre-roll time from 1 to 30 seconds.
3
Press the [ENTER] button to activate your selection, or the [CANCEL] button
4
to cancel the Pre Roll function.
Press the [UTILITY] button again to leave utility.
5
The UTILITY indicator goes out.
Setting the Post-roll Time
The post-roll time can be set from 1 to 30 seconds, the default being 5 seconds.
Press the [UTILITY] button.
1
The UTILITY indicator lights up.
Use the JOG/DATA dial to select "POST ROLL," and then press the [ENTER]
2
button.
The currently set post-roll time appears on the display.
Use the JOG/DATA dial to set the post-roll time from 1 to 30 seconds.
3
Press the [ENTER] button to activate your selection, or the [CANCEL] button
4
to cancel the Post Roll function.
Press the [UTILITY] button again to leave utility.
5
The UTILITY indicator goes out.
D24—Owner's Manual
Pre-roll
LAST REC IN
point
point
Pre-roll
time
LAST REC OUT
Post-roll
point
point
Post-roll
time